Analytical Method Development and Validation of Baricitinib:

A Comprehensive Review of RP-HPLC and Spectroscopic Techniques

 

Sangramsing Dipaksing Deshmukh, Amitkumar Rajkumar Dhankani,

Mansi Amitkumar Dhankani, Sunil Pandit Pawar

Department of Pharmaceutical Quality Assurance, P.S.G.V.P. Mandals College of Pharmacy, Shahada.

Kavayitri Bahinabai Chaudhari North Maharashtra University, Jalgaon 425004. Maharashtra India.

*Corresponding Author E-mail: sangramsingdeshmukh@gmail.com

 

ABSTRACT:

Baricitinib is an orally administered, selective Janus kinase (JAK1 and JAK2) inhibitor widely prescribed for the management of rheumatoid arthritis and other inflammatory disorders. Owing to its expanding clinical applications and therapeutic importance, the development of robust, precise, and stability indicating analytical methods is essential to ensure its quality, safety, and efficacy in pharmaceutical formulations. This review comprehensively summarises the analytical approaches reported for the estimation of Baricitinib in bulk drug and dosage forms, with particular emphasis on reverse-phase high-performance liquid chromatography (RP-HPLC). The discussed RP-HPLC methods demonstrate excellent performance characteristics in accordance with ICH validation guidelines, including accuracy, precision, linearity, specificity, range, limit of detection (LOD), limit of quantification (LOQ), robustness, and ruggedness. In addition to chromatographic techniques, complementary methods such as UV–Visible spectroscopy, UHPLC, HPTLC, and LC-MS/MS are also highlighted. Overall, validated analytical methodologies play a critical role in pharmaceutical quality control, regulatory compliance, and stability assessment, ensuring consistent therapeutic performance of Baricitinib-containing formulations.

 

KEYWORDS: Baricitinib, RP-HPLC, Analytical method validation, JAK inhibitor, Pharmaceutical quality control.

 


 

INTRODUCTION:

Baricitinib is an orally active, selective Janus kinase (JAK1 and JAK2) inhibitor used in the treatment of rheumatoid arthritis and other inflammatory disorders. By modulating cytokine-mediated signalling pathways through inhibition of the JAK–STAT pathway, Baricitinib reduces inflammation and immune activation. Given its increasing therapeutic use and availability in tablet dosage forms, the development of reliable, validated analytical methods is essential to ensure the compound's identity, purity, potency, and quality.1

 

Analytical method development plays a critical role in pharmaceutical quality control, formulation development, stability studies, and regulatory compliance. Reverse-phase high-performance liquid chromatography (RP-HPLC) is one of the most widely used techniques for the quantitative estimation of Baricitinib due to its high sensitivity, specificity, accuracy, and reproducibility. Additionally, UV spectrophotometric and stability-indicating methods have also been reported for its analysis in bulk drugs and pharmaceutical formulations.2

 

Mechanism of Action:

Baricitinib inhibits the JAK–STAT signaling pathway. Cytokine binding normally activates JAK enzymes, leading to STAT phosphorylation and transcription of inflammatory genes. Baricitinib blocks this pathway by inhibiting JAK1 and JAK2 enzymes, thereby reducing inflammation.3

 

Physicochemical Properties of Baricitinib:4,5

Table 1: Physicochemical Properties of Bar

Parameter

Description

Chemical Name

(2S)-1-(ethylsulfonyl)-3-[4-(7H-pyrrolo[2,3-d] pyrimidin-4-yl)-1H-pyrazol-1-yl] azetidine-2-carbonitrile

Molecular Formula

C₁₆H₁₇N₇O₂S

Molecular Weight

371.42g/mol

Drug Class

Janus kinase (JAK1/JAK2) inhibitor

Physical Appearance

White to off-white crystalline powder

Melting Point

214–218°C

pKa Value

4.0 (weakly basic heterocyclic nitrogen)

Solubility

Slightly soluble in water; soluble in methanol and DMSO

Functional Groups

Pyrrolopyrimidine ring, pyrazole ring, sulfonyl group, nitrile group

 

Chemical Structure5

 

 

Chemical Structure of Baricitinib:

Pharmacokinetics of Baricitinib:

Baricitinib exhibits predictable pharmacokinetics following oral administration, supporting once-daily dosing. Its absorption, distribution, metabolism, and elimination pathways have been characterised in healthy volunteers and patients with rheumatoid arthritis.6,7

 

Absorption:

Baricitinib is rapidly absorbed after oral administration, with peak plasma concentrations (Tmax) generally reached within approximately 1hour (range 0.5–3hours). The drug demonstrates high oral bioavailability of 79–80%, and food has minimal clinically relevant effect on systemic exposure, allowing administration with or without meals.7

 

Distribution:

Once absorbed, Baricitinib is distributed into tissues beyond the plasma compartment. The apparent volume of distribution (Vd) is about 76 L, indicating extensive tissue distribution. It is moderately bound to plasma proteins, with approximately 50% bound.8

 

Metabolism:

The metabolic transformation of Baricitinib is minimal. Less than 10% of an administered dose is metabolised, primarily by the cytochrome P450 isoenzyme CYP3A4. Metabolites are generally not quantifiable in plasma, suggesting that the parent compound largely accounts for its pharmacological activity.9

 

Elimination:

The primary route of elimination for Baricitinib is renal excretion. Approximately 75% of the administered dose is excreted in urine, predominantly as unchanged drug, with around 20% eliminated in faeces. The elimination half-life (t₁/₂) in healthy subjects and patients with rheumatoid arthritis is approximately 12–16hours, supporting once-daily dosing.10

 

Special Populations:

In individuals with renal impairment, systemic exposure (AUC) increases with the severity of renal dysfunction, and dose adjustments may be required. Moderate hepatic impairment does not significantly affect Baricitinib pharmacokinetics. Age, sex, body weight, and race generally do not cause clinically meaningful differences in pharmacokinetic parameters.11

 

Pharmacodynamics:

Baricitinib is a selective, orally active Janus kinase (JAK) inhibitor that primarily targets JAK1 and JAK2, which play central roles in cytokine-mediated immune signalling pathways. By inhibiting these kinases, baricitinib suppresses intracellular signalling through the JAK–STAT pathway, thereby reducing inflammatory and immune responses.12

 

Analytical Method Development:

According to ICH Q2 (R1), method validation provides documented evidence that a particular process will reliably produce the intended result at the required quality standard. Said, it is the process that proves that analytical methods are suitable for the intended use and support the identity, quality, purity, and potency of drug substances and drug products. Method validation is necessary when new techniques are developed, and different analysts in different labs use the methods. The performance standards required to validate the method.13

Method Validation:

The development of reliable analytical methods is essential for the quantitative determination of Baricitinib in bulk drug and pharmaceutical dosage forms. Reverse-phase high-performance liquid chromatography (RP-HPLC) is widely used for its accuracy, sensitivity, reproducibility, and suitability for routine pharmaceutical analysis.

 

In the reported analytical study, an RP-HPLC method was developed and optimised for the estimation of Baricitinib using a C18 stationary phase and UV detection. Chromatographic separation was achieved under optimised conditions that produced a sharp, symmetrical peak with good resolution.14

 

Parameters of method validation:15

1.     Accuracy

2.     Precision

3.     Linearity

4.     Specificity

5.     Range

6.     Limit of Detection

7.     Limit of quantification

8.     Robustness

9.     Ruggedness.

 

1.     Accuracy:

Accuracy was evaluated by recovery studies using the standard addition method at different concentration levels. The percentage recovery values were 98–102%, indicating that the method is accurate for the quantitative estimation of Baricitinib16.

 

2.     Precision:

Precision was assessed using repeatability and intermediate precision. The percentage relative standard deviation (%RSD) values were within acceptable limits (<2%), confirming the method's precision.16

 

3.     Linearity:

Linearity was established by preparing calibration standards in the concentration range of 12–28 µg/mL. The calibration curve showed a strong linear relationship between concentration and peak area with a correlation coefficient of 0.9995.16

 

4.     Specificity:

Specificity of the method was confirmed by the absence of interfering peaks from excipients or solvents at the Baricitinib retention time, demonstrating selective detection of the analyte.17

 

5.     Range:

The analytical method demonstrated acceptable accuracy, precision, and linearity over the concentration range of 12–28µg/mL, thereby establishing the working analytical range.17

6.     Limit of Detection (LOD):

The LOD for Baricitinib was found to be approximately:

5.004µg/mL

This indicates the method's sensitivity in detecting small amounts of the drug17.

 

7.     Limit of Quantification (LOQ):

The LOQ was determined to be:

15.164µg/mL

This confirms the minimum concentration that can be quantified with acceptable accuracy and precision.18

 

8.     Robustness:

Robustness was evaluated by making small variations in chromatographic parameters, such as:

i)   Flow rate

ii) Mobile phase composition

iii)           Detection wavelength

 

No significant changes in retention time or peak area were observed, indicating that the method is robust.19

 

9.     Ruggedness:

Ruggedness was determined by performing the analysis under different conditions, such as:

i)   Different analysts

ii) Different instruments

iii)           Different days

 

The results remained consistent, confirming method ruggedness.20

 

Chromatographic Technique:

UV–Visible (UV/Vis) spectroscopy is a fundamental analytical technique widely used in pharmaceutical and analytical chemistry for both qualitative and quantitative analysis of chemical substances. Qualitative analysis aims to determine the identity of an analyte, whereas quantitative analysis provides a numerical measurement of its concentration in a given sample. UV–Visible spectroscopy serves as a rapid, reliable, and cost-effective tool for both purposes.21

 

Analytical chemistry encompasses traditional wet chemical methods as well as modern instrumental techniques. Among these, UV–Visible spectroscopy remains one of the most commonly employed instrumental methods due to its simplicity, reproducibility, and applicability to a broad range of organic and inorganic compounds.22

 

High-Performance Liquid Chromatography (HPLC) is a highly efficient form of column chromatography widely used in biochemistry, pharmaceutical analysis, clinical research, and analytical sciences for the separation, identification, and quantification of active pharmaceutical ingredients (APIs), impurities, degradation products, and biological samples.

HPLC operates at high pressure to achieve rapid, high-resolution separation of components in complex mixtures. Due to its sensitivity, reproducibility, and versatility, HPLC is considered the gold standard technique in pharmaceutical quality control laboratories.23

 

Ultra-High-Performance Liquid Chromatography (UHPLC):

Ultra-High-Performance Liquid Chromatography (UHPLC), also known as Ultra-Performance Liquid Chromatography (UPLC), is an advanced form of high-performance liquid chromatography that improves analytical performance in sensitivity, speed, and chromatographic resolution. UHPLC technology represents a significant development in liquid chromatographic separation by employing columns packed with very small particle sizes (typically < 2µm) and operating at higher system pressures than conventional HPLC systems.

 

The fundamental principle of UHPLC is similar to that of HPLC, where separation occurs due to differential interactions between analytes and the stationary and mobile phases. However, improvements in column packing technology and instrumentation allow UHPLC systems to achieve superior separation efficiency.24

 

Reverse Phase High-Performance Liquid Chromatography:

Reverse-phase high-performance liquid chromatography (RP-HPLC) is one of the most widely used chromatographic techniques for analytical separation, identification, and quantification of compounds in biological, chemical, pharmaceutical, and biomedical sciences. Due to its versatility, reproducibility, and compatibility with a wide range of drug molecules, RP-HPLC has become the preferred chromatographic method in pharmaceutical analysis.25

 

High-Performance Thin-Layer Chromatography:

High-Performance Thin-Layer Chromatography (HPTLC) is an advanced form of thin-layer chromatography (TLC) that offers improved separation efficiency, enhanced automation, greater sensitivity, and greater reproducibility compared to conventional TLC methods. Because of these advantages, HPTLC has become an important analytical technique in pharmaceutical and industrial laboratories.

 

HPTLC combines the simplicity of planar chromatography with modern instrumentation, allowing both qualitative and quantitative analysis of complex mixtures.26

 

Reported Method For Baricitinib:

Baricitinib is a widely used Janus kinase (JAK1/JAK2) inhibitor used in the management of autoimmune and inflammatory disorders, including rheumatoid arthritis. The development of reliable analytical methods is essential to ensure their efficacy, safety, and quality in pharmaceutical applications. Over the years, researchers have explored various analytical procedures for quantifying Baricitinib in both bulk drugs and marketed formulations. Some of the commonly employed techniques include UV spectrophotometry and reverse-phase high-performance liquid chromatography (RP-HPLC), which have significantly improved the accuracy, precision, and reproducibility of Baricitinib analysis.27

 

In 2022, Santhosh Illendula developed and validated an accurate, precise, and rapid RP-HPLC method for determining Baricitinib in both bulk and marketed pharmaceutical dosage forms. Better separation of the drug was achieved on Develosil ODS HG-5 RP C18, 5µm, 15cm x 4.6mm i.d. with the mobile phase consisting of a mixture of Methanol and Phosphate buffer (0.02M, pH 3.6) in a ratio of 45:55v/v at a flow rate of 1.0ml/min, with detection at 255nm using a UV detector. The retention time was 3.254min. The method was found to be linear over the range of 12-28 µg/ml, with a correlation coefficient (r2) of 0.9995. The LOD and LOQ of the method were calculated to be 5.004 and 15.164μg/ml, respectively. The Precision was estimated using repeatability and intra-day and inter-day studies, and the results were calculated as %RSD values, which were within the limits. Recovery of Baricitinib was found to be in the range of 98-102-% which confirms the accuracy of the method.28

 

Table 2: Summary of validation parameters of method development by Santhosh Illendula etal.

Parameter

Condition

Mobile phase

Methanol: Phosphate buffer (0.02 M, pH 3.6) = 45:55

Column

Develosil ODS HG-5 RP C18, 5 µm, 15 cm × 4.6 mm i.d.

Column Temperature

Ambient

Detection Wavelength

255nm

Flow rate

1.0mL/min

Run time

07min

Temperature of the Auto sampler

Ambient

Diluent

Mobile Phase

Injection Volume

20µL

Type of Elution

Isocratic

Retention Time

3.254min

 

S. Mohan and his co-workers published this research work in 2019. We propose that the method is simple, as the selected chromatographic Conditions are not difficult to apply in routine analysis for testing the chromatographic impurity of baricitinib. A reverse-phase UPLC method for the estimation of related substances (chromatographic impurities) in Baricitinib was developed and validated. Baricitinib was developed by separating its degradation products on an X-Terra RP18 (150x4.6mm, 5.0µm) column using 0.1% Triethylamine in water adjusted to pH 2.5 with OPA and Acetonitrile in a simple gradient at a flow rate of 1.0ml/min. The column effluents were monitored by a photodiode array detector set at 224nm. The method was validated for specificity, linearity, accuracy, precision, detection limit, quantification limit, and robustness. Forced degradation of Baricitinib was carried out under acidic, basic, peroxide, reduction, thermal, photo and hydrolysis conditions29.

 

Table 3: Summary of validation parameters of method development by S. Mohan etal

Parameter

Condition

Column

X-Terra RP18 (150 × 4.6mm, 5.0µm)

Mobile Phase A

0.1% Triethylamine in water (pH adjusted to 2.5 with OPA)

Mobile Phase B

Acetonitrile

Elution Mode

Gradient

Flow Rate

1.0mL/min

Detector

Photodiode Array (PDA)

Detection Wavelength

224nm

Retention Time

12min

 

Kiran Kumar Gannamani to develop a method for determining Baricitinib and its related compounds, and to confirm its stability under various conditions and forced degradation methods using reverse-phase HPLC. The separation was performed using an inert-sustain C8 column with a 4.6mm internal diameter, 250mm long, which is loaded with Octyl silane chemically bound to porous silica particles of 5μm diameter, with a flow rate of 1ml per minute, UV detection of 225nm, and a column oven temperature of 45°C. The total time required to acquire data was fifty minutes.30

 

Table 4: Summary of validation parameters of method development by Kiran Kumar Gannamani etal.

Parameter

Condition

Column

Inert-Sustain C8 column (250mm × 4.6mm i.d., 5 µm particle size, octyl-silane bonded porous silica)

Flow Rate

1.0mL/min

Detection Method

UV Detector

Detection Wavelength

225nm

Column Oven Temperature

45°C

Run Time

50min

Retention Time

10.821min

 

Khagga Bhavya Sri1, the treatment of moderate-to-severe rheumatoid arthritis, severe alopecia areata, and, since 2022, COVID-19 in hospitalised adults requiring supplemental oxygen. This drug acts as a selective inhibitor of Janus kinase 1 and 2. This study aimed to establish and validate a stability-indicating UV spectroscopic method for measuring baricitinib in both bulk and formulated forms. A straightforward, precise, and cost-effective UV method was developed using dimethylformamide (DMF) and distilled water as the solvent. To prepare the standard stock solution, 10mg of baricitinib was dissolved in 1mL of DMF and then diluted with distilled water. Subsequent dilutions were prepared with distilled water and analysed at 309nm. The validation of this method was performed according to ICH Q2 R (2) guidelines. The method demonstrated linearity in the concentration range of 10-100μg/mL with an excellent correlation coefficient (r˛ = 0.999). The precision results were within the acceptable range, and the % RSD was less than 2.0.31

 

 

Table 5: Summary of validation parameters of method development by Khagga Bhavya etal.

Parameter

Condition

Solvent System

Dimethylformamide (DMF) and distilled water

Standard Stock Preparation

10mg drug dissolved in 1mL DMF and diluted with distilled water

Diluent

Distilled water

Detection Wavelength

309nm

Linearity Range

10–100μg/mL

Correlation Coefficient (r˛)

0.999

Precision (%RSD)

Less than 2.0%

Validation Guideline

ICH Q2(R2)

 

 

CONCLUSION:

Baricitinib is an orally active, selective JAK1/JAK2 inhibitor with well-established therapeutic efficacy in rheumatoid arthritis and other inflammatory disorders. Its targeted inhibition of the JAK–STAT signalling pathway effectively reduces cytokine-mediated inflammation, while its predictable pharmacokinetics support convenient once-daily dosing.

 

Given its expanding clinical application, the development of precise, accurate, and stability-indicating analytical methods is essential to ensure identity, purity, potency, and overall quality. Among the available techniques, RP-HPLC remains the most reliable and widely adopted method due to its sensitivity, specificity, reproducibility, and suitability for routine quality control. Validation parameters—including accuracy, precision, linearity, specificity, LOD, LOQ, robustness, and ruggedness—confirm the reliability of the reported methods in accordance with regulatory guidelines.

 

Additionally, complementary techniques such as UV–Visible spectroscopy, HPLC, UHPLC, and HPTLC further strengthen analytical capabilities for bulk drugs and pharmaceutical formulations.

 

Overall, validated analytical methodologies play a crucial role in supporting formulation development, stability assessment, and regulatory compliance, ensuring the consistent safety and therapeutic effectiveness of Baricitinib.

 

 

REFERENCES:

1.      O’Shea, J. J., Schwartz, D. M., Villarino, A. V., Gadina, M., McInnes, I. B., and Laurence, A. (2015). Janus kinase inhibitors in autoimmune diseases (pp. ii111–ii115). Annals of the Rheumatic Diseases, 74(Suppl 2).

2.      International Council for Harmonisation (ICH). (2005). ICH Q2(R1): Validation of Analytical Procedures — Text and Methodology. Geneva.

3.      O’Shea, J. J., Schwartz, D. M., Villarino, A. V., Gadina, M., McInnes, I. B., and Laurence, A. Janus kinase inhibitors in autoimmune diseases. Annals of the Rheumatic Diseases. 2015; 74(Suppl 2): ii111–ii115.

4.      Eli Lilly and Company. (2018). Olumiant (Baricitinib) prescribing information. Indianapolis, USA.

5.      National Centre for Biotechnology Information. (2024). PubChem Compound Summary: Baricitinib. Available from the PubChem database.

6.      Shi, J. G., Chen, X., Lee, F., Emm, T., Scherle, P. A., Lo, Y., et al.  The pharmacokinetics, pharmacodynamics, and safety of baricitinib in healthy subjects. Clinical Pharmacology in Drug Development. 2014; 3(5): 367–374.

7.      Choy, E. H., Miceli-Richard, C., González-Gay, M. A., Sinigaglia, L., Schlichting, D. E., Meszaros, G., et al. Pharmacokinetic profile of baricitinib in patients with rheumatoid arthritis. Rheumatology and Therapy. 2018; 5(2): 461–472.

8.      Taylor, P. C., Keystone, E. C., van der Heijde, D., Weinblatt, M. E., Del Carmen Morales, L., Reyes Gonzaga, J., et al. Baricitinib versus placebo or adalimumab in rheumatoid arthritis. New England Journal of Medicine. 2017; 376(7): 652–662.

9.      U.S. Food and Drug Administration. (2018). Clinical Pharmacology Review: Baricitinib (Olumiant).

10.   National Centre for Biotechnology Information. PubChem Compound Summary: Baricitinib.

11.   Zhang, X., Peck, R., Van Brummelen, P., and Gupta, P. Population pharmacokinetics of baricitinib in patients with rheumatoid arthritis. Clinical Pharmacokinetics. 2017; 56(12): 1523–1534.

12.   Fridman, J. S., Scherle, P. A., Collins, R., Burn, T., Li, Y., Li, J., et al. Selective inhibition of JAK1 and JAK2 by baricitinib and its impact on cytokine signalling. Journal of Immunology. 2010; 184(9): 5298–5307

13.   International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use. (2005). ICH Q2(R1): Validation of Analytical Procedures — Text and Methodology. Geneva.

14.   Ramole Rina, Mohini Baile, Ashish Jain. 

15.   Hokanson GC.A life cycle approach to the validation of analytical methods during pharmaceutical product development, Part I: The initial validation process. Pharm.Tech. 1994; 118–30.

16.   Sahoo NK, Sahu M, Veerachamy A, Lalitha BV, Moharana AK, Sahoo CK. Quantification and validation of simvastatin and ezetimibe in bulk drugs and combined dosage form by reverse phase liquid chromatographic method (RPLC). Pharm.Methods 2015; 6(2): 115–9.

17.   Sahoo NK, Sahu M, Alagarsamy V, Srividya B, Sahoo CK. Current status of two-dimensional gel validation of assay indicating method development of imatinib in bulk and its capsule dosage form by liquid chromatography. Ann. Chromatogr Sep. Tech.2015; 1(2): 1010.

18.   Moharana AK, Banerjee M, Sahoo CK, Sahoo NK. Development and validation of an RP-HPLC method for mesalamine. Asian J. of Pharmaceutical and Clinical Research 2011; 4(Suppl.2):71–73.

19.   Reddy V.P, Rajan T.V.S, Kumar A. N, A Review on Analytical Method Validation. Int J Rev Life Sci. 1: 141–144.

20.   Chinmaya K. S, Muvvala S., Nalini K. S., Validation of Analytical Methods: A Review, International Journal of Chromatography and Separation Techniques. 2018;1

21.   Nagdev, S. A., Bhurat, M. R., Usman, M. R. M., Gupta, K. R., and Gandagule, U. B. (2019, January). Pharmaceutical Quality Assurance (pp. 3–4).

22.   Venkateswarlu, K., Devanna, N., Haritha, A., and Farihath, M. S. (2013). UV-Visible Spectroscopy. PharmaTutor Articles.

23.   Vidushi, Y., and Meenakshi, B. A review of HPLC method development and validation. Life Science Informatics Publications, RJLBPCS. 2017; 2(6). 

24.   UKEssays. (2018, November). Review of Ultra High-Performance Liquid Chromatography and High-Performance Liquid Chromatography.

25.   Gupta, S., Verma, P., Mishra, A. P., Omar, N., and Mathur, R.  A review of novel analytical method development and validation by the RP-HPLC method. Indian Journal of Forensic Medicine and Toxicology. 2021; 15(4).

26.   Ramole, R., Baile, M., and Jain, A. (). A review: Analytical method development and validation. Systematic Review in Pharmacy. 2021; 12(8).

27.   Eleni Kakouri1 Identification and structural characterisation of potential degradation products of baricitinib using liquid chromatography combined with quadrupole time-of-flight mass spectrometry. Acta Chromatographica. 2024 Apr; 37(1): 6–108.

28.   Illendula S, Prasad PS. Analytical method development and validation of RP-HPLC for the quantitative determination of baricitinib in pure substances and marketed formulations. International Journal of Pharmacy and Biological Sciences. 2022 Jul; 12(3): 108–14.

29.   S. Mohan, N Srinivasarao. Development and validation of a stability-indicating related substances method of baricitinib by RP-HPLC and its degradation. International Journal of Management and Humanities. 2019 Mar; 4(2): 4–9.

30.   Kiran Kumar Gannamani Development and validation of stability-indicating RP-HPLC method for the determination of baricitinib and its related drug substances. Rasayan Journal of Chemistry. 2023 Aug; 16(3): 1163–73.

31.   Khagga Bhavya Sri1 Development and validation of a stability-indicating UV spectroscopic method for baricitinib in bulk and formulation. Pharmaceutical Sciences and Drug Design. 2022 Aug; 2: 8–13.

32.   J´ er´ emie Tachet Development and validation of a multiplex HPLC-MS/MS assay for monitoring JAK inhibitors in patient plasma. Journal of Chromatography B. 2023 Oct; 1230: 1–9.

 

 

 

 

 

Received on 08.04.2026      Revised on 16.05.2026

Accepted on 18.06.2026      Published on 12.10.2026

Available online from October 21, 2026

Asian Journal of Pharmaceutical Analysis. 2026; 16(4):279-284.

DOI: 10.52711/2231-5675.2026.00043

©Asian Pharma Press All Right Reserved

 

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License. Creative Commons License.